{"product_id":"5-mm-path-jgs1-quartz-sealed-screw-top-cuvette-optical-contact-fused-2-or-4-clear-windows-large-small-screw-cap-200-2500-nm","title":"5 mm Path JGS1 Quartz Sealed Screw-Top Cuvette, Optical-Contact Fused, 2 or 4 Clear Windows, Large \/ Small Screw Cap, 200–2500 nm","description":"\u003ch2\u003e5 mm Path JGS1 Quartz Sealed Screw-Top Cuvette\u003c\/h2\u003e\u003cp\u003eShort-path quartz cuvettes with an integrated threaded neck and screw cap for leak-free, evaporation-resistant measurements. The body is made by optical-contact fusing, so there is no adhesive layer that could contaminate samples. Available with two clear windows for absorbance or four clear windows for fluorescence, with a large or small screw cap and round or flat bottom.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePath length:\u003c\/strong\u003e 5 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e JGS1 UV-grade fused quartz, usable from 200 to 2500 nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmittance:\u003c\/strong\u003e above 80% (about 83% typical), matched-pair error of 0.5% or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal:\u003c\/strong\u003e threaded neck with screw cap prevents leakage and evaporation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdhesive-free construction:\u003c\/strong\u003e optical-contact fused body resists acids, solvents and heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed sample:\u003c\/strong\u003e suitable for volatile solvents, air-sensitive samples and long kinetic runs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo window options:\u003c\/strong\u003e 2 clear windows for UV-Vis absorbance; 4 clear windows for fluorescence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCap and bottom options:\u003c\/strong\u003e large or small screw cap; round or flat bottom.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModel Comparison\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eClear windows\u003c\/th\u003e\n\u003cth\u003eScrew cap\u003c\/th\u003e\n\u003cth\u003eBottom\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2W, large cap\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eLarge\u003c\/td\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003ctd\u003eAbsorbance, easy filling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2W, small cap\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003ctd\u003eAbsorbance, low dead volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4W, large cap\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eLarge\u003c\/td\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003ctd\u003eFluorescence, easy filling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4W, small cap\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003ctd\u003eFluorescence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4W, small cap, flat bottom\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003ctd\u003eFluorescence, stable standing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCommon Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhen should I use a screw-top cuvette?\u003c\/strong\u003e Use it when the sample is volatile, toxic, oxygen-sensitive or must be measured over a long time, since the cap keeps the contents sealed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e2 or 4 windows?\u003c\/strong\u003e Absorbance needs only two clear windows in the light path. Fluorescence detection at 90° needs all four sides clear.\u003c\/p\u003e\u003ch3\u003eUse and Care\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTighten the cap gently; do not overtighten.\u003c\/li\u003e\n\u003cli\u003eClean with ultrapure water, ethanol or a quartz cleaning solution; avoid hydrofluoric acid and hot strong alkali.\u003c\/li\u003e\n\u003cli\u003eDo not wipe optical windows with hard or abrasive materials.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eFor research and laboratory use only.\u003c\/em\u003e\u003c\/p\u003e","brand":"Alabsupply","offers":[{"title":"2 Windows\/Large Screw Cap, Round Bottom","offer_id":68293482479836,"sku":"PUR-QSC05-2W-LS","price":109.0,"currency_code":"USD","in_stock":true},{"title":"2 Windows\/Small Screw Cap, Round Bottom","offer_id":68293482512604,"sku":"PUR-QSC05-2W-SS","price":103.0,"currency_code":"USD","in_stock":true},{"title":"4 Windows\/Small Screw Cap, Round Bottom","offer_id":68293482545372,"sku":"PUR-QSC05-4W-SS","price":135.0,"currency_code":"USD","in_stock":true},{"title":"4 Windows\/Small Screw Cap, Flat Bottom","offer_id":68293482578140,"sku":"PUR-QSC05-4W-SS-FB","price":145.0,"currency_code":"USD","in_stock":true},{"title":"4 Windows\/Large Screw Cap, Round Bottom","offer_id":68293482610908,"sku":"PUR-QSC05-4W-LS","price":141.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/3474\/1724\/files\/S5f60c80ce4694a4e895aee808dd3ae83a.webp?v=1794770538","url":"https:\/\/alabsupply.com\/products\/5-mm-path-jgs1-quartz-sealed-screw-top-cuvette-optical-contact-fused-2-or-4-clear-windows-large-small-screw-cap-200-2500-nm","provider":"Alabsupply","version":"1.0","type":"link"}