{"product_id":"heating-and-cooling-circulator","title":"Heating and Cooling Circulator","description":"\u003cp\u003eThis refrigeration and heating integrated circulation device (water bath) provides heating, refrigerating and circulating temperature control for laboratory equipment such as evaporators and extraction setups. Six tank capacities are available (5L, 10L, 20L, 30L, 50L and 100L) at per-capacity prices verified on the source page - see the comparison table below for the specifications shared by all capacities.\u003c\/p\u003e\u003ch3\u003eModel Comparison\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e5L\u003c\/th\u003e\n\u003cth\u003e10L\u003c\/th\u003e\n\u003cth\u003e20L\u003c\/th\u003e\n\u003cth\u003e30L\u003c\/th\u003e\n\u003cth\u003e50L\u003c\/th\u003e\n\u003cth\u003e100L\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003ctd\u003eWater Bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003ctd\u003eHeating, Refrigerating \u0026amp; Circulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003ctd\u003e-20°C ~ +200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003ctd\u003eR22 \/ R404A \/ R407C \/ R134A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Type\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003ctd\u003eFully Enclosed Rotary Compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003ctd\u003e1.5-5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation Method\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003ctd\u003eAir-cooled and hermetically sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003ctd\u003e220-240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eVoltage note for US customers: This unit operates on 220V. Standard US outlets supply 110–120V, so a 220V circuit or a suitable step-up transformer is required.\u003c\/p\u003e","brand":"Alabsupply","offers":[{"title":"5L","offer_id":67899242741980,"sku":"ALAB-5L-YH","price":1656.0,"currency_code":"USD","in_stock":true},{"title":"10L","offer_id":67899245134044,"sku":"ALAB-10L-YH","price":2022.0,"currency_code":"USD","in_stock":true},{"title":"20L","offer_id":67899245789404,"sku":"ALAB-20L-YH","price":2206.0,"currency_code":"USD","in_stock":true},{"title":"30L","offer_id":67899247034588,"sku":"ALAB-30L-YH","price":2573.0,"currency_code":"USD","in_stock":true},{"title":"50L","offer_id":67899247362268,"sku":"ALAB-50L-YH","price":2942.0,"currency_code":"USD","in_stock":true},{"title":"100L","offer_id":67899247984860,"sku":"ALAB-100L-YH","price":4044.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/3474\/1724\/files\/img_01_clean_10b2b3d5-c890-4fdc-b9a7-1e19ed07ee4f.jpg?v=1792991349","url":"https:\/\/alabsupply.com\/products\/heating-and-cooling-circulator","provider":"Alabsupply","version":"1.0","type":"link"}