Laboratory Overhead Stirrer, Digital / Knob Control, 10–60 L, LES / DNP / BKD Series
Laboratory Overhead Stirrer, Digital / Knob Control, 10–60 L, LES / DNP / BKD Series
Regular price
$131.25 USD
Regular price
Sale price
$131.25 USD
Shipping calculated at checkout.
Laboratory overhead (electric) stirrers for mixing low-, medium- and high-viscosity liquids, and liquid/solid mixtures, in chemical synthesis, biopharmaceuticals, food and beverage, and other fields. Three series: general-purpose LES, research-grade DNP and professional BKD, with knob-controlled or digital timer models.
Features
- LES general-purpose series: permanent-magnet DC motor with constant-power compensation; durable and reliable
- DNP research series: high speed-control accuracy with 5 speed-memory presets; motor and overload protection
- BKD professional series: brushless DC motor for high-viscosity, high-load and long continuous operation; fault display with automatic stop; remote control capable
- Suitable for liquid/liquid and solid/liquid mixing experiments that require strict speed control
Specifications
- Power supply: 220 V, 10 A grounded outlet
- Applications: chemical synthesis, biopharmaceuticals, food and beverage, pharmaceutical, chemical and biotechnology laboratories
Model Comparison
| SKU | Model | Series | Control | Max. Stirring Volume (H2O) | Recommended Max. Viscosity | Motor | Speed Range | Speed Accuracy | Timer | Motor / Overload Protection |
|---|---|---|---|---|---|---|---|---|---|---|
| BKM-OSTI-001 | LES-10L | General-purpose | Knob | 10 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-002 | LES-15L | General-purpose | Knob | 15 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-003 | LES-20L | General-purpose | Knob | 20 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-004 | LES-10LT | General-purpose | Digital with timer | 10 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-005 | LES-15LT | General-purpose | Digital with timer | 15 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-006 | LES-20LT | General-purpose | Digital with timer | 20 L | 2,000–8,000 mPa·s | Permanent-magnet DC | 100–2,000 rpm | 10% (digital models) | 1–999 min (digital models) | — |
| BKM-OSTI-007 | DNP-20L | Research | Knob | 20 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-008 | DNP-40L | Research | Knob | 40 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-009 | DNP-60L | Research | Knob | 60 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-010 | DNP-20LS | Research | Digital with timer | 20 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-011 | DNP-40LS | Research | Digital with timer | 40 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-012 | DNP-60LS | Research | Digital with timer | 60 L | 10,000–30,000 mPa·s | Permanent-magnet DC | 50–3,000 rpm | ±3 rpm (digital models) | 1–999 min (digital models) | Yes |
| BKM-OSTI-013 | BKD-60S | Professional | Digital with timer | 20 L | 15,000–60,000 mPa·s | Brushless DC | 30–2,200 rpm | ±1 rpm | 1–9,999 min | Yes (fault display, auto stop) |
| BKM-OSTI-014 | BKD-120S | Professional | Digital with timer | 40 L | 15,000–60,000 mPa·s | Brushless DC | 30–2,200 rpm | ±1 rpm | 1–9,999 min | Yes (fault display, auto stop) |
Input power: LES 72–200 W; DNP 60–200 W; BKD 60/120 W. Display: LES LED, DNP and BKD LCD (digital models).
Precautions
- Electrical safety: use a dedicated grounded 220 V/10 A outlet; never plug or unplug with wet hands; do not damage or modify the power cord.
- Hazardous media: only for media that do not react dangerously during processing. Handle toxic or volatile media in closed containers inside a fume hood.
- Monitoring: if the impeller runs off-center, stirs unevenly or the medium splashes, stop immediately and adjust. If the instrument moves, stop and stabilize it.
- Installation: center the impeller in the vessel without touching the wall or bottom; tighten the impeller from bottom to top to prevent slipping; do not disassemble or adjust parts; use only original spare parts.
- Faults: disconnect power immediately and contact after-sales service; do not repair yourself.
- Cleaning: clean the impeller promptly after use to prevent residue; unplug when not in use for a long time and store in a cool, dry place.