Purcise SLT Polyethersulfone (PES) 0.2 μm Sterilizing-Grade Bricap T Capsule Filter, Low Cytotoxicity. Sold in the configuration options listed below; specifications are as published by the manufacturer.
Specifications
- Filter Format: Bricap™ T Capsule Filter
- Scale: Production Scale
- Filtration Area: 0.55 m², 1.1 m², 1.65 m²
- Pore Size: 0.2 μm (final-filter)
- Pre-filter: 0.45 μm
- Bubble Point (per 0.55 m²): ≥0.34 MPa at 20 °C, water wetted, air
- Membrane Material: Polyethersulfone (PES)
- Support Fleece: Polypropylene (PP)
- Housing: Polypropylene (PP)
- O-ring / Seal: Silicone
- Max. Differential Pressure (Forward): 0.55 MPa at 25 °C0.1 MPa at 80 °C
- Max. Differential Pressure (Reverse): 0.21 MPa at 25 °C
- Compliance: USP <788> Particulate MatterUSP <87> CytotoxicityUSP <88> Biological ReactivityFDA Indirect Food Additives, 21 CFR 177-182ADCF Materials
- Bacterial Retention: 10⁷ cfu/cm² Brevundimonas diminuta (ATCC 19146) according to ASTM F838
- Bacterial Endotoxin: Endotoxin Limit of WFI System<0.25 EU/mL with the Limulus Amebocyte Lysate (LAL), USP <85>
- Non-Fiber Releasing: The products meet the criteria as defined in 21 CFR 210.3(b)(6)
- Sterilization Method: Autoclavable: 25 cycles for 30 min at 130 °C (SIP not compatible)Gamma Compatible: can be sterilized by gamma irradiation or be autoclaved 5 cycles for 60 min at 126 °CPre-sterilized: by gamma irradiation at 25–45 kGyPre-sterilized: by autoclaved packed in cleansteam bag
- Pack Size: Pack of 1
- Packaging: Individually packed in a double PE bag
Model Comparison
| SKU | Capsule Format | Connectors | Sterility |
|---|---|---|---|
| COB-SPP6-1 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-2 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-3 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-4 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Autoclaved) |
| COB-SPP6-5 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-6 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-7 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-8 | T10 (0.55 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Autoclaved) |
| COB-SPP6-9 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-10 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-11 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-12 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Autoclaved) |
| COB-SPP6-13 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-14 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-15 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-16 | T20 (1.1 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Autoclaved) |
| COB-SPP6-17 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-18 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-19 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-20 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 1 1/2" Sanitary (without Gauge Port) | Sterile (Autoclaved) |
| COB-SPP6-21 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Autoclavable) |
| COB-SPP6-22 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Non-sterile (Gamma Compatible) |
| COB-SPP6-23 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Gamma Irradiation) |
| COB-SPP6-24 | T30 (1.65 m²) | Inlet: 1 1/2" Sanitary + Outlet: 3/4" HB (without Gauge Port) | Sterile (Autoclaved) |