Stifle Distractors for small veterinary orthopedic surgery in pet animals. Designed to separate the femoral component of the stifle from the tibia for examination of the joint.
Features
When closed, the tips of the Stifle Distractor overlap. This reduces the profile of the tips and minimises the chance of iatrogenic damage when inserting the device into the joint space.
Designed to separate the femoral component of the stifle from the tibia.
For the best exposure, joint surfaces should move away from each other in a parallel fashion, exposing the meniscus in its natural state & minimally distorted by the examination.
Positioning
One tip is placed in the intercondylar notch
The other on the cranial intercondylar area
Neither tip should involve articular cartilage
Test distraction (by squeezing the handles) to find the exact point at which a full distraction will expose the meniscus
Engage the spinlock to open the joint
Specifications
Item
Specification
Size
Min Spread 8mm, Max Spread 30mm, 190mm Long
Use
Veterinary use only — small animal / pet orthopedic surgery